A press box is a small building that happens to be twenty feet in the air, and it is the most expensive single option on most grandstands. Planned early it is a straightforward structure on the back of the stand; planned late it is a change order with its own foundation. Here is what to settle before the drawings are final.
Who is in it
Start with the people, not the square footage. A high school press box typically holds the announcer, the clock and scoreboard operator, both coaching staffs (often separated by a wall), a few media seats, and a camera position on the roof. Colleges add radio and television booths, a video board operator, statistics and a working press area. Race tracks add race control, timing and scoring, the flag stand and VIP suites. Write the list, give each person about 30 inches of counter, and the width of the box follows.
| Typical use | Width | Depth | Notes |
|---|---|---|---|
| Small school or park | 16 to 20 ft | 8 ft | Announcer, clock, two coaching positions |
| High school stadium | 24 to 32 ft | 8 to 10 ft | Add media seats, separate coaching rooms, roof camera deck |
| College or large venue | 40 ft and up | 10 to 12 ft | Multiple booths, broadcast, stats; often two levels |
| Race track | 24 to 40 ft | 10 to 12 ft | Race control, timing and scoring, flag stand, suites |
Where it sits
Centered on the 50-yard line (or the start/finish line) at the back of the stand, with the floor at or just above the top row so the box does not block the view from the seats behind it. On a stand with a rear cross aisle, the box sits behind that aisle and the aisle becomes its front access. The roof is usually the camera deck, reached by a ladder or a stair from inside the box, with a guard around it.
Access and the ADA exception
Press boxes have a specific exception in the 2010 ADA Standards. An accessible route is not required to a press box that is in bleacher seating with entry at only one level, or that is free-standing and elevated 12 feet or more above grade, as long as the total area of all press boxes at the venue is 500 square feet or less. Most high school press boxes fit inside that limit. Go larger, or put a press box where it has entry at more than one level, and it needs an accessible route, which usually means a platform lift or an elevator. That decision belongs in the first planning meeting because it changes the structure and the budget.
What runs to it
- Power: dedicated circuits for the PA, the scoreboard controls, broadcast equipment and HVAC, in conduit sleeved under the stand before the footings are poured.
- Data: fiber or Ethernet to the box and to the camera deck. Broadcasters and video boards need it; so does a modern scoreboard.
- Lightning protection and grounding for a metal box on top of a metal stand.
- HVAC: a heat pump or a mini-split keeps the box usable in September and November. Plan the condenser location and the condensate drain.
- Water: rarely, but if there is a restroom or a sink, plan it now.
Common press box designs
Most press boxes we draw are one of four layouts. The right one depends on the stand under it and how many people need a seat.
- Stand-mounted, one level. The box sits on the back of the grandstand, centered on the field, with the roof as a camera deck. The most common design for high school and park stadiums.
- Two levels. The announcer, clock and coaches below; radio, video and media above. Common at colleges and larger venues, and the reason to engineer the stand for it from the start.
- Freestanding tower. Its own columns and foundation beside or behind the stand, used where the stand is too small to carry it or the best sightline is elsewhere. Common at race tracks for race control.
- Modular or prefabricated. A factory-built box set on the stand by crane. It shortens the time on site, but it still needs the same structure, access, power and data planned under it, and it is held to the same code as a box built in place.
Whatever the design, the structure under it is the expensive part, which is why the press box goes on the drawings before the stand is final.
Windows, counters and the small things
- Sliding or drop windows along the front, with counter height at 36 inches so people can work standing or seated.
- A solid counter the full width, and power at the counter every few feet.
- Interior walls where coaching staffs need to be separated, with their own doors.
- Exterior lighting on the roof deck, and a hatch or door that can be secured.
- Lettering and branding on the fascia: this is the part of the stadium that is in every photo.
If the press box is not in this year’s budget, have the stand engineered for it now. Leaving the connections, the rear platform and the conduit ready costs very little; adding them to a finished stand costs a lot.
Every grandstand we draw shows the press box, the camera deck and the access route whether or not they are in the first phase. Tell us who needs to be in yours.